Revit family host greyed out. Is there any way to make the pulls offset parameter available in a project? Dec 19, 2018 · Helping out a lighting consultant: I have some recessed can lights they are in the correct location but they have no host. Go to Modify tab -> Host panel -> Pick New Host tool. Share your knowledge, ask questions, and explore popular Revit Architecture topics. Here are the steps: From the Identity Data section of the Properties Pallet, select the option next to View Template. Obviously one would think that the grayed out parameters are formula driven but these are not. Highlight the nested family, click on Visibility in the option bar and "When cut in Plan/ RCP is grayed out. Feb 8, 2016 · I had a look at the family. Jan 16, 2018 · I am trying to adjust visiblity of a linked architectural model, but when I get to Visibility/Graphics >> Revit Links >> Display settings (Custom) >>; Basics tabI have no option to choose "By linked view" - it is grayed out. I want to change the Display Settings to by Linked View. If the situation occurs in the full version of Revit LT: The model was created in a full version of Revit, and the elements are on a design option. See attached. " message during tagging the revision cloud. Apr 18, 2018 · But in my case using "By host view" the elements are gone. Any hints would be appreciated! Best Tom Jan 12, 2015 · component level greyed out: Revit Building >> Technical Support. So during placing you have to check that you select the proper face (ceiling). How to change the greyed-out parameters in Revit? Is there any way to edit or hide them? Causes: Jul 14, 2022 · Hey Guys, so i have a pendant light revit family that i am trying to edit and just extend the length on it but I haven't been able to unlock the properties. It seems the out of box ADESK content won't let you modify this parameter. Also if I look at a 3d view or a section view it does not appear. Each family is Jul 2, 2010 · The problem occurs when I try to insert a family. To move a host-based component to a different host: Select the component you want to move. 1. I go into Visibility/Graphics, then the Revit Links tab and the links are greyed out. G Cash +63 945 745 07 83 Dec 29, 2017 · Hi all. Ive included the host and nested models, but i cannot include the project file. So i have to use by linked view, and select the layout (view) that i created in that hosted file. I tried to load a curtain wall family into my project. In the family it was dash dot dot and in the project it became thicker and solid. Any thoughts on this behavior. for some reason when i o to file export the families tab is greyed out. Oct 8, 2023 · When using Load Family in Revit from the Vault Addin, the button is greyed out after selecting a rfa file. This means it will stick to all possibe faces, not only ceilings. Oct 8, 2023 · Issue: The field to edit a parameter in a Revit family is grayed out and cannot be edited when the family is loaded into another family or Revit project file. You may want to check the active view, its Parameters, and Visibility settings, as well as any Plan Regions and their settings. I have a question. They seem to be locked, I cant find a formula that's locking them though. I am cleaning up our families and template and would like the behaviour to be consistent (or at least controlled). Just another 20 mins of my day gone solving the never-ending Revit riddle. Note here in Figure 2 that the Description does not have a formula, but the has the Value of the description in quotes. e inaccessible, in specific family types and appear active as usual in the others. Unfortunately we cannot modify the setting that controls how Feb 25, 2014 · Welcome to Autodesk’s Revit Architecture Forums. when This family is placed on a mass surface, the Repeater is greyed out. Thanks Feb 15, 2017 · I am using Revit 2016, and was attempting to make a tag for duct fittings which shows "UP" or "DN" and an arrow. The hardware is easily swapped in a project but the pulls, while centered on the drawer, are off the edge of the doors. Wed, May 13, 2009 at 7:36:11 PM. If the situation occurs in the full version of Revit: Exclude Options box at the bottom of the drawing window is activated. Oct 1, 2019 · Welcome to Autodesk’s Revit Architecture Forums. So even if you go into the View Graphics of the Revit Links and make a custom view where you turn off everything but the Ceilings category, it still won't work? Aug 5, 2009 · If you go to the Light family, and click on family types, you will see the parameter. The family you are using is a Face based family which you hosted to Level 1? Select it >> on the ribbon >>> pick new host and you should see the hosting options (Vertical Face/Face/Workplane) Oct 16, 2018 · Hi, in the project attached there is a vessel that I downloaded from the manufacturer site but it seems there are some sort of constraints maybe in the parameters . Problem with revit family (attic stairway) Revit Building >> Technical Support. I tried to find the original source of the family but they do not exist in our imperial library. One of them allows for the HT to be picked and moved, i. Jul 19, 2023 · When working with Revit families, it is essential to be familiar with the different types of parameters that exist within Revit. Instead, use “Pick New Host”tool. View. You now see that one of the lines (Heavy Lines) changed. It's finicky when trying to place it on the correct host level (despite it seemingly attaching to the wall) is there a way to adjust the level constraint in the properties? it it grayed out and I can't On a family like the the "outlet floor - single" electrical fixture, a stock revit symbol, can the properties "Electrical - Loads" be modified? Their fields are grayed out. I added a note to the help to explain it. Jun 8, 2012 · With Identity Data expanded, you may see grayed out parameters. Basically parameters that have formulas become non-editable parameters and are hence grayed out. Share your knowledge, ask questions, and explore popular Revit MEP topics. The problem is we have inserted and positioned these components in the family editor using Dynamo to automate certain processes. Furthermore when I try in "Custom" mode to adjust "View range" - the only option available is "By host view". I really need to associate these parameters in the host family for it ot work, but the little button next to the parameter doesnt exist when its grayed out please help Dec 27, 2017 · Hello, I am trying to change families' levels in my project but when cutting and pasting to a selected level, it still assigns a different level then the one I select. May 29, 2020 · Hello, I try to place light families in Revit with GH. So you could re-create it and make it an instance. I checked the object styles and the VG menu and they are both the same as the ductwork yet appear to be greyed out (see below). There should be a default Level called "Floor Line" or something like that. My structural plans are "looking up", while architects "down". For the other one, however, it doesn't and it is greyed out on the Instance Properties. Jan 18, 2018 · Welcome to Autodesk’s Revit MEP Forums. Sep 17, 2018 · Hi all, I downloaded a manufacturer's revit family ( a urinal carrier) and it loads into the specialty equipment category. Sun, Aug 31, 2014 Aug 21, 2019 · For some reason when I try to file export the families tab is greyed out. Anyone have an idea of what it is happening with Apr 4, 2023 · what version of Revit are you using. can anyone help me in working out how to fix this? Hello, I have a file which i was wanting to export all the revit families out of. The level remains grayed out unless a new host is picked. (I think they are all wall hosted families so far, sinks, wc's, toilet partitions, etc) Even if I change the work plan of the view they always seem to insert at the same level, and the "level" parameter in the properties dialog is greyed out. Within component families for example, there are 3 types: Built-in parameters that are hard coded within the program and can be used to adjust geometry and be tagged and scheduled once loaded into a project. Dec 21, 2019 · Having downloaded a family from a Revit website, in the pictures and in the family, it is showing the materials and colors but when inserted into the project shows default grey finish. They just sit on the face of the ceiling. 2. Copy/monitor Aug 9, 2024 · Some elements or families can't be selected in a Revit model. Notice that Mark is active, but Image is not editable. Basically when a formula only has one variable, both values can be worked out using the math so you are able to change the value directly (and the variable will be calculated and changed), or indirectly (the variable parameter is changed and the formula is used to calculate the value. Feb 1, 2012 · The Host in the properties reads: Linked Revit Model: and then the name of the architectural revit model that I have linked. Dec 26, 2017 · Solved: I'm using Revit 2017 and I can't figure out why my "level" button is greyed out, I'm in elevation view but cannot create levels. I reference a model line which is on the face and reference the host ceiling with the host component but the place family component always drops the light somehow below the ceiling not even close and far from cutting anything. Feb 8, 2024 · I'm creating a generic family and while in sketch mode some of the dimensions that I am creating appear in black text and are selectable, while other dimensions, while creating in sketch mode, appear in grayscale and are not selectable until completing the sketch mode and coming back to family mode. Initially, I created a project parameter Sub-discipline but it has been grayed out in the properties pallet. Mon, Oct 7, 2013 at 1:32:26 PM. If it actually reads "Wall", then the Family is limited to being hosted to an actual Wall. Sep 7, 2009 · (I have also shared the nested families under Setting>Families Categories and Parameters. Fri, May 10, 2013 at 7:15:14 AM. I have a Adaptive family, with 4 adaptive Placement points, and 1 adaptive Shape Handle point. You can't change the host. Dec 13, 2006 · The pull family offset parameter works wonderfully in the cabinet family, but is greyed out when the cabinet family is loaded into a project. I just checked a 2020 model and when placing an itme on face, I have and the offset from host option i did not see that option in your screen capture though. This is not happening with the other families. But once I tried to use the family I cannot locate the whereabouts of the family which I loaded (not in window, wall or even in Component view). I can add shared parameters to labels but in the Family Feb 13, 2020 · Solved: When I select an element and choose "Edit type" to see the properties, they are all greyed out so I cannot make a duplicate or edit Forums Home Revit Products Community Oct 8, 2023 · Make the parent family visible along with the shared (nested) family: Turn on the Reveal hidden elements mode (if there are other settings which could hide the parent family, adjust these as well so that both the host and nested family are displayed at the same time). e. Again, there's almost no way to control what level Revit will pick. Dec 2, 2013 · A similar question came up recently somewhere else. Keep in mind, when your using ADESK content, it's meant to be generic and not specific. Nested family missing when host family is loaded into project: Revit Building >> Technical Support. Tue, Feb 26, 2008 at 7:01:51 PM. We need some parameters to be greyed out,i. Nov 25, 2010 · Nested Family referencing Host family: Revit Building >> Technical Support. Jan 10, 2018 · When the family is placed on a floor plan and inside the boundary of a floor, it is hosted by the floor. I was then going to have a label that displayed the text. Does Revit need to know where the original source is in order to make it editable? Oct 28, 2018 · After placing a host-based component, if you would like to move it another host, Move tool will not be very effective. This works great but now there is no way to edit the workplane May 4, 2013 · Welcome to Autodesk’s Revit Architecture Forums. I load the nested families into the host family. May 14, 2018 · Hello, currently my project browser is bit messy. I attached the file. If I go to edit type, the load button is grayed out? If I open out families in the project browser, go to profiles and go the M_Slab Edge-Thickened, I see there are some families there for a t Wall Hosted Simple Family In RevitHelp Support My Channel. It is just not efficient to explore every permutation of why something unexpected is happening in Revit. I can see the family is loaded into the project from the Project Browser. I tried to edit the family but couldn't find those properties in the family. Do a search in Revit Help for "hosted families", and non Jun 14, 2021 · An additional reference inside the family, similarly- works fine if the existing family is not too complex and the rework will not take significant time. Forums Home Revit Products Community Mar 9, 2016 · The idea was to make it an instance so that we would align that RefPlane to the face of the Wall it needs reporting to. Sep 10, 2019 · Whenever a wall hosted component is placed on a wall in 3D Revit picks the nearest convenient level and locks it to that level. Hope that makes it clear. The issue is the light sources for the light fixtures which are in the linked file are somehow keeping Revit from seeing the face in the linked file. , it shows the grips. My goal is to be able to use this one family to create multiple arrays of parking spaces but be able to schedule each array as a different classification. 0 Sep 16, 2021 · That is a reporting parameter you cannot change it. In orer to eliminate Nov 13, 2013 · On the left the detail item inside the project, on the right the detail item family. Constraining a group parameter to reference levels: Revit Building >> Technical Support. If I use "pick new host", choose "face" and place them, they will host to the ceiling, but they won't recess. When you load the family into your project, and then place the tub, Revit is "looking" for a host ( if it is a hosted family ) Hope this helps a bit. If I "create similar", the new light fixture recesses correctly into the ceiling just fine. So, here’s the trick. 8. Apr 11, 2014 · If you open the Family and open the "Family Category and Parameters" dialog, and at the bottom, scroll down to "Host", which should read "Face". I don't remember when that started though. Group accross Level of Different Heights: Revit Building >> Technical Support. I figured that the problem is the button to switch between Depth and Height is always greyed out and I can Sep 11, 2020 · ALL of the options to select at the bottom of the screen are greyed out in addition yo EVERYThING else! I am able to zoom in and out of the drawing, open other sheets. You can fix the ones buried inside the floor by simply select them and change the Offset value. The "M-Ceiling Light - Flat Round" family is a face based family. So, if you want to change the offset and keeping the association with its host, set the offset distance by parameter in the family. The Load Family button is now visible Mar 23, 2022 · Hi all, Is there a way with Dynamo to set the workplane/ host of an element in the family editor. Select the item to be deleted. Jul 14, 2017 · Well, what you can’t do is open the family and change it there, as in the Family Category and Parameters, you will see the Host parameter and value greyed-out. You need to host the family properly so that it reports properly . Step 1 When the shelves are loaded into a project and then you click on the properties of the element under constraints "Host" is grayed. Feb 15, 2024 · The visibility settings in Revit can become greyed out if there’s a view template applied to the view that has the visibility settings locked. Parameter greyed out: Parameter available to edit: Jan 31, 2019 · I have linked in two Revit Architectural projects into a host project. We have 2 windows in the project (file attached). The rfa file needs to be clicked because only variants can be loaded to Vault. Dec 11, 2015 · Dear All, I'm getting that famous "None of the created elements are visible in Floor Plan: . Jun 23, 2008 · Right click on family name and the edit option is greyed out. I need to host certain nested components to reference lines because they are driven by angle parameters.   Jul 25, 2014 · One of my nested families has most of its parameters grayed out in the host family. If the Shape Handle point is deleted from the adaptive family, the Repeater becomes active. Apr 20, 2020 · However, it is greyed out and there seems to be no way to change it or link it to another parameter. The placed family is grayed out for new host or working plane selection. To adjust the settings, you can modify the view template. This actually happens with several Jan 23, 2020 · I was placing walls before I went out for lunch. (and my host view has all elements checked, model categories and annotation categories) (might be some stupid tick-mark or something in my layout options. All give me the same response - greyed out This happened after editing a cloud on a detail, after I selected the green tick to complete the editing (resizing) of the cloud, the cloud disappeared. I figure this has to be a Discipline issue, but I have it set to "Mechanical" Discipline, so sho May 9, 2013 · Using these conditional statements, the sole purpose of the visibility parameter check-boxes is destroyed as all these appeared greyed out, though either on/off. When I load it into plan view in the drawing I can see it but cannot select it. I want to show the annotations and fill regions etc. When I tried to take off from where I started, the wall seem to go in the downward from level 1 to level -1 . Even when rendered. Aug 22, 2011 · Revit 2015, R2, update 6. I came back and I have a problem. ) May 5, 2017 · Hello, I seem to have a problem with my duct fittings coming in greyed out. idk, i just now that now it works) Mar 29, 2019 · If you have a need to edit elements in a group, you will notice that if you tab and select something, that some element properties can be changed and some cannot. I can place it easily in 3D view, but it sometimes associates with the incorrect level. Is this normal behavior - that the Feb 13, 2018 · Hi When I click on slab edge in the structure tab, first of all there are no preloaded families there. so I planned to create sub-discipline folder so that I can move some of the secondary plans. Design options are disabled by default in Revit LT Aug 29, 2018 · Anytime something is greyed out, Revit should let you know why- say by an info box when you hover over. Try and load it into a generic project to see what my problem is. Double-click on the rfa file and select a variant. Aug 28, 2009 · Open the Family editor, and take a look at an elevation view. Wed, Jan 10, 2018 at 5:00:30 AM. A couple workarounds are: To place the elements by reference plane, and select the face the ceiling. The families with this greyed out are unable to be moved vertically (including by unchecking “disjoin”). so i can't move this component vertically but only horizontally, I also verified the offset but the options to modify it are greyed out Sep 15, 2011 · I am stumped. Load the family into Project and the panels do not cut in Plan or RCP. . I even loaded into a new family template but it is till being hosted by the floor. Is there any way to break this restriction Sep 21, 2016 · I have a generic downspout family. when trying to change the specific family's level in properties - the level selction is greyed out. Please see screenshots for 2 examples. in 2023, when using place on face, you get an offset from host option. Further you see that the new object style was created in the family is now added to the project. From what I've noticed you can disconnect the family from the schedule level but it still doesn't give a full freedom to move the family up and down without having to point to a new plane. I plan on purging these families out, but was curious to know what would make a family un-editable. I want the plan view to be linked into a plan view. Or use a work plane based family in stead of face based. Oct 8, 2023 · When trying to place a light fixture by face on a ceiling which is in a linked file, Revit does not allow you to place the element. On the same project, with the same Central file, the same exact Electrical Fixture instance allows me to rehost it in one computer and NOT on another (yes after it has been relinquished during a synchronization to the central file) the Pick New Work Plane button greys out after one second and can't be rehosted using that computer. Jul 26, 2017 · I forgot to mention that when you move a face based equipment off the host, it will become non-host. The "M-Ceiling Light - Flat Round" does not contain parameters for offset. I was going to add shared parameters, one yes/no checkbox for up, and a text parameter that was "UP" if up was checked or "DN" if it was unchecked. huh vsdrju xsf aurqk uvqvpq isvgwl trhxia wjbpp zjwfly uigqykwh